Description
Details
TO BE USED WITH 120 VOLT OR 240 VOLT SINGLE PHASE POWER
Purpose
The lightning arrestor is designed to protect motors and controls from voltage surges caused by lightning, switching loads, or power line interferences. Surges of 500 volts or more are directed to ground by the lightning arrestor. Although the arrestor may or may not take repeated surges, no arrestor can withstand a direct lightning strike or a surge of unusually high voltage.
Application
The Heavy-Duty Models lightning arrestor have Threads and Nut to Attach to Electrical Panel or varieties of enclosed motor controls.
Including:
WELL PUMP CONTROLS (2 WIRE OR 3 WIRE MOTORS)
1. Pressure Switch
2. Control Box
3. Both the pressure switch and control box
Note: Pressure switch arrestor location offers the best water system protection, if only one lightning arrestor is used.
WARNING: It is very important that all electrical work be done properly. Therefore, only a qualified electrician or electrical service man should perform the initial hook-up and any electrical service thereafter! All local electrical codes must be followed.
Purpose
The lightning arrestor is designed to protect motors and controls from voltage surges caused by lightning, switching loads, or power line interferences. Surges of 500 volts or more are directed to ground by the lightning arrestor. Although the arrestor may or may not take repeated surges, no arrestor can withstand a direct lightning strike or a surge of unusually high voltage.
Application
The Heavy-Duty Models lightning arrestor have Threads and Nut to Attach to Electrical Panel or varieties of enclosed motor controls.
Including:
WELL PUMP CONTROLS (2 WIRE OR 3 WIRE MOTORS)
1. Pressure Switch
2. Control Box
3. Both the pressure switch and control box
Note: Pressure switch arrestor location offers the best water system protection, if only one lightning arrestor is used.
WARNING: It is very important that all electrical work be done properly. Therefore, only a qualified electrician or electrical service man should perform the initial hook-up and any electrical service thereafter! All local electrical codes must be followed.
Features and Accessories
Product Features
- (MOV) Varistors Used for Positive Discharge of High Voltage Surges
- 120 / 240 Volt Single Phase Installations
- For Surges of 500 + Volts - High Voltage Directed to Ground Wire
- Heavy-Duty Models Have Threads and Nut to Attach to Electrical Panel
- Application: Lightning Arrestor Can Be Used with a Variety of Enclosed Motor Controls.
Lightning arrestors have a unique feature unlike other secondary lightning arrestors in that they can be checked with a conventional ohmmeter.
With arrestor removed from circuit:
1. Set selector knob on ohmmeter to RX100K.
2. Connect both black "lightning arrestor" leads to one ohmmeter lead.
3. Connect white "lightning arrestor" lead to the other ohmmeter lead.
4. Resistance should read infinity (00). If a resistance reading other than infinity (00) is attained, the "lightning arrestor" should be replaced.
Specifications
Additional Info
Specifications | |
---|---|
Manufacturer | Merrill |
Model # | LAHD550 |
Shipping Weight | 1 |
Product Literature
Product Literature
(Size: 9.3 KB)