› Well/Pressure Tanks
› Booster Pumps
› Water Softeners
› pH neutralizers for acidic waters, to raise the pH
› Catalox Filters for Removal of Iron, Manganese & Hydrogen Sulfide
› Birm Filters for Removal of Iron & Manganese
› Greensand Filters for Removal of Iron, Manganese & Hydrogen Sulfide
› Greensand Plus Filters for Removal of Iron, Manganese & Hydrogen Sulfide
› Centaur Carbon Filters for Removal of Hydrogen Sulfide
› GAC Filters for Removal of Taste, Odor & Volatile Organic Chemicals
› Oxygen Chamber Systems with Catalox Filters
› Oxygen Chamber Systems with Birm Filters
› Oxygen Chamber Systems with Centaur Carbon Filters
› Cartridge Filter Housings and UV Filters
› UV Disinfection Systems and Replacement Parts
› Reverse Osmosis Drinking Water Systems
› Jet Pumps
› Submersible Well Pumps
› Well Pump Control Boxes, Protectors, and Motors
› Submersible Pump Protection Separators
› Well Accessories
› Fleck Control Valves
› Filtration Media
› Water Conditioning Chemicals
› Radon Mitigation Systems
› Chemical Feed Systems
› Commercial Booster Systems
› Dry Pellet Chlorinator
› Mineral Tanks

› Terms and Conditions
› Shipping/Return Policy
› Frequently Asked Questions
› Drinking Water Standards

› Amtrol
› B & B Chlorination
› Clack Corporation
› Davey Pumps
› Fleck
› Franklin Pumps
› GE
› Goulds Pumps
› Grundfos
› Hydrotech
› Nimbus
› Pentair
› Pentek
› Pura
› Sterilight
› Trojan
› Walrus Pumps
› Wedeco

 
 
Home > Well Pump Control Boxes, Protectors, and Motors
Coyote Pump Protectors
Coyote Pump Protectors
See Models and Features Below
Price Prices Include Shipping. See Description
Availability:
In Stock
Choose Options and Quantity
Select Model Number
Quantity
 
 Description

Pump Protectors

Coyote Pump Protectors

The Coyote Pump Protector protects pump motors by automatically shutting them off

when they are at risk of low or high voltage, overload, rapid cycling, or running dry. Four

models are available to suit your specific needs.

• Easy to install

• Automatically resets itself if turned off

• Protects both 2 & 3 wire motors from 1/3 to 2 HP

• Protects pumps by shutting them off due to:

Failure to pump fluid due to gas or air lock, clogged inlet,

or lack of fluid, low voltage, high voltage, rapid cycling

overload

• Restarts automatically with adjustable timer

• Inside wiring is sealed from outside elements

• Exceptional flexibility

Operates alone, with pressure or float switches, or tank

pump-up controls

FEATURES

Super

115V 1/3-1HP model:

230V 1/3-2HP model:

Protects against running dry, too low or too

high of voltage, overload, and rapid cycling.

Also allows users to activate an alarm.

Basic

115V 1/3-1HP model:

230V 1/3-2HP model:

Protects against running dry and low voltage.

Pump Protectors

Coyote Pump Protectors Specifications

Coyote Pump Protector Super Models: 115 Volt & 230 Volt

  • Horsepower rating ..................1/3-1HP (115V), 1/3-2HP (230V)
  • Alarm ..........................Able to activate a light, bell or most any other alarm desired. The Coyote dry alarm contact is normally open, but will close on any fault condition.
  • Random start............................When powered at the circuit breaker or fused disconnect, a delay of 4 to 10 seconds occurs before the
  • Coyote turns the pump on. This prevents several pumps served by a single power source from all restarting at the same instant when power is restored after power outage.
  • Underload or lack of fluid: The Coyote shuts off the pump within one second of running dry and automatically restarts the pump after a designated amount of time (1 minute to 12 hours).
  • Trip delay ............................1 second
  • Reset delay ........................adjustable; 1 minute to 12 hours 
  • Overload: The microprocessor circuit notes the normal running current of the pump motor. If the Coyote shuts the pump down due to excessive current, it will restart it in 60 seconds. If at that time the motor draws normal current, then the Coyote will allow it to run. If however, the motor continues to draw excessive current after two consecutive attempts, one minute apart, the Coyote locks out the pump so as not to burn out a motor winding. The overload light then changes from steady to blinking. 
  • Trip amps ............................150% of normal load
  • Trip delay ............................1/4 second
  • Reset delay ........................60 seconds
  • Voltage Fault: +2%
  • Trip delay ............................2 seconds (both models)
  • Reset delay ........................60 seconds (both models)
  • Voltage trip..........................95V (115V),1 90V (230V),135V (115V), 270V (230V)
  • Voltage reset ......................100V (115V), 200V (230V), 130V (115V) ,260V (230V)
  • Coyote Pump Protector Basic Models: 115 Volt & 230 Volt
  • Horsepower rating ..................1/3-1HP (115V), 1/3-2HP (230V)
  • Trip delay ..................................1/4 seconds
  • Reset delay ..............................adjustable; 5 minutes to 5 hours
  • Operating temperature ............-20º to 75º
  • Trip % of normal load ............adjustable
  • Voltage trip ..............................110V (115V), 190V (230V)
  • Voltage reset ............................106V (115V), 202V (230V)
 Related Items
Franklin Control Boxes For 3-Wire Motors
Prices include Shipping. See Description
Franklin Pumptec Control and Pumptec
Prices Include Shipping. See Description
Goulds 2-Wire, 4" Submersible Well Pumps Without Control Box, 5GS series
Prices Include Shipping. See description
Review this item
To Speak With a Systems Engineer Please Call 1-800-767-8731
Copyright © 2008 Aqua Science. All Rights Reserved. ecommerce software powered by 3DCart.